Crown Boiler AWI162 User Manual

CROWN  
Boiler Co  
AWI & TWI Series  
Gas-Fired Natural Draft Hot Water Boilers  
INSTALLATION INSTRUCTIONS  
These instructions must be affixed on or adjacent to the boiler  
Models:  
AWI037  
WARNING: Improper installa-  
tion, adjustment, alteration,  
AWI061  
AWI095  
AWI128  
AWI162  
AWI195  
AWI229  
AWI262  
AWI295  
TWI061  
TWI095  
TWI128  
TWI162  
service or maintenance can  
cause property damage, injury,  
or loss of life. For assistance or  
additional information, consult a  
qualified installer, service  
agency or the gas supplier.  
Read these instructions carefully  
before installing.  
CROWN  
Boiler Co  
Manufacturer of Hydronic Heatings Products  
P.O. Box 14818 3633 I. Street  
Philadelphia, PA 19134  
Table of Contents  
I. Product Description .................................................. 1  
VIII. System Piping ............................................. 12  
IX. Wiring ......................................................... 16  
II. Specifications ............................................................ 1  
III. Before Installing ......................................................... 4  
IV. Locating the Boiler ...................................................... 4  
V. Air for Combustion & Ventilation .............................. 5  
VI. Venting ....................................................................... 8  
VII. Gas Piping ................................................................ 11  
X.  
Start-Up & Checkout .................................. 21  
XI. Service & Maintenance............................... 27  
XII. Troubleshooting ......................................... 29  
XIII. Parts ............................................................ 34  
I Product Description  
The AWI series boiler is a cast iron gas fired water boiler designed for use in closed forced circulation heating systems.  
This boiler is a Category I draft diverter equipped appliance, which must be vented by natural draft using a lined masonry  
or listed metal chimney system. An adequate supply of air for combustion, ventilation and dilution of flue gases must be  
available in the boiler room.  
The TWI series boiler is identical to corresponding sized AWI boiler except for the addition of baffles in the flue passages  
to obtain higher AFUEs. The TWI is not available with a standing pilot or for use with propane gas.  
II Specifications  
FIGURE1A: STANDARDCONFIGURATION(SEEPAGE3FORLETTERDIMENSIONS)  
1
FIGURE1B:LEFTPIPEDCONFIGURATION  
FIGURE1C:TOPPIPED(T-AWIORT-TWI) CONFIGURATION  
2
TABLE1:SPECIFICATIONS  
RATINGS - NATURAL AND LP GASES*  
DIMENSIONS (INCHES)  
BASIC  
BOILER  
MODEL  
DOE  
HEATING  
CAPACITY  
I=B=R NET  
RATING,  
WATER  
INPUT  
AFUE  
%
NUMBER  
OF  
"A"  
"B"  
"C"  
"D"  
"E"  
"F"  
SECTIONS  
MBH  
37  
MBH  
30  
MBH  
26  
AWI037S  
AWI037E  
80.0  
82.3  
2
3
10-1/2  
11-3/4  
15  
7-1/4  
5-7/8  
7-1/2  
9-1/8  
10-3/4  
12-3/8  
14  
4
4
5
6
6
7
7
8
8
3-5/8 3-7/8  
AWI061S  
AWI061E  
80.0  
82.6  
61  
95  
50  
43  
68  
3-5/8  
4-1/8  
4-5/8  
4-5/8  
5-1/8  
5-1/8  
5-5/8  
5-5/8  
1-7/8  
1-7/8  
1-7/8  
1-7/8  
1-7/8  
1-7/8  
1-7/8  
1-7/8  
AWI095S  
AWI095E  
80.1  
82.3  
27-7/8  
4
78  
AWI128S  
AWI128E  
80.2  
82.0  
5
128  
162  
195  
229  
262  
295  
105  
132  
159  
186  
212  
238  
91  
18-1/4  
21-1/2  
24-3/4  
28  
AWI162S  
AWI162E  
80.3  
81.7  
6
115  
138  
162  
184  
207  
AWI195S  
AWI195E  
80.4  
81.4  
7
AWI229S